|
|
Connection
|
[SerializableAttribute] public class ConnectionParameters : ConnectionParametersBase
The ConnectionParameters type exposes the following members.
| Name | Description | |
|---|---|---|
| ConnectionParameters | Creates a new ConnectionParameters. | |
| ConnectionParameters(SerializationInfo, StreamingContext) | Creates a new ConnectionParameters from serialization parameters. |
| Name | Description | |
|---|---|---|
| Algorithm | Gets or sets the PhaseEstimationAlgorithm used to derive synchrophasor, frequency and ROCOF components from SEL CWS point-on-wave data. | |
| CalculatePhaseEstimates | Gets or sets flag that determines if current and voltage phase estimates, frequency and dF/dt should be calculated for PoW data. | |
| CalculationFrameRate | Gets or sets the configured frame rate for phase estimate calculations. | |
| EnableIntervalAveraging | Gets or sets a flag that determines if interval averaging (boxcar averaging) is enabled across each publish interval when down-sampling. | |
| EnablePublishEMA | Gets or sets a flag that determines if an additional exponential moving average (EMA) is applied to the published stream (after interval averaging). | |
| FilterClass | Gets or sets the IEEE C37.118 filter class: P (Protection, fast response) or M (Measurement, better out-of-band rejection). | |
| MaxGapFillSamples | Gets or sets the maximum gap (in input samples) filled by phase-continued synthesis before resynchronizing. | |
| NominalFrequency | Gets or sets the nominal LineFrequency of this SEL CWS device. | |
| PublishAnglesTauSeconds | Gets or sets the EMA time constant τ (seconds) for published phase angles. | |
| PublishFrequencyTauSeconds | Gets or sets the EMA time constant τ (seconds) for published frequency. | |
| PublishMagnitudesTauSeconds | Gets or sets the EMA time constant τ (seconds) for published RMS magnitudes. | |
| PublishRocofTauSeconds | Gets or sets the EMA time constant τ (seconds) for published ROCOF (dF/dt). | |
| RecalculationCycles | Gets or sets the number of nominal cycles between full DFT recalculations for numerical stability. | |
| ReferenceChannel | Gets or sets the reference channel for frequency tracking. | |
| RepeatLastCalculatedValueWhenDownSampling | Gets or sets flag that determines if last value should be repeated when down-sampling, i.e., when CalculationFrameRate is less than SEL CWS frame rate (commonly 3000Hz); otherwise NaN will be used. | |
| SampleFrequencyTauSeconds | Gets or sets the EMA time constant τ (seconds) for the internal per-sample frequency smoothing that occurs inside the estimator before any down-sampling/publish filtering. | |
| SampleRocofTauSeconds | Gets or sets the EMA time constant τ (seconds) for the internal per-sample ROCOF smoothing (computed from the internally smoothed frequency). | |
| TargetCycles | Gets or sets the number of nominal cycles contained in the sliding DFT analysis window. | |
| ValuesAreValid |
Determines if custom connection parameters are valid.
(Inherited from ConnectionParametersBase) |
| Name | Description | |
|---|---|---|
| Equals | Determines whether the specified object is equal to the current object. (Inherited from Object) | |
| Finalize | Allows an object to try to free resources and perform other cleanup operations before it is reclaimed by garbage collection. (Inherited from Object) | |
| GetHashCode | Serves as the default hash function. (Inherited from Object) | |
| GetObjectData |
Populates a SerializationInfo with the data needed to serialize the target object.
(Overrides ConnectionParametersBaseGetObjectData(SerializationInfo, StreamingContext)) | |
| GetType | Gets the Type of the current instance. (Inherited from Object) | |
| MemberwiseClone | Creates a shallow copy of the current Object. (Inherited from Object) | |
| ToString | Returns a string that represents the current object. (Inherited from Object) |
| Name | Description | |
|---|---|---|
| DefaultAlgorithm | Default value for Algorithm. | |
| DefaultCalculatePhaseEstimates | Default value for CalculatePhaseEstimates. | |
| DefaultRepeatLastCalculatedValueWhenDownSampling | Default value for RepeatLastCalculatedValueWhenDownSampling. |
| Name | Description | |
|---|---|---|
| GetEnumValueOrDefault |
Gets the enumeration constant for value, if defined in the enumeration, or a default value.
(Defined by EnumExtensions) | |
| GetEnumValueOrDefaultT |
Gets the enumeration constant for this value, if defined in the enumeration, or a default value.
(Defined by EnumExtensions) |