              Name | 
              Description | 
            
            
              
                 
                 
               | 
              
                AngleFund
               | 
              
            Value of the power angle at fundamental frequency. 
             | 
            
            
              
                 
                 
               | 
              
                ANSITDF
               | 
              
            Transformer derating factor.
             | 
            
            
              
                 
                 
               | 
              
                ArithSum
               | 
              
            Arithmetic sum.
             | 
            
            
              
                 
                 
               | 
              
                AvgImbal
               | 
              
            Imbalance by max deviation from average.
             | 
            
            
              
                 
                 
               | 
              
                CrestFactor
               | 
              
            Crest factor.
             | 
            
            
              
                 
                 
               | 
              
                DAxis
               | 
              
            D axis components.
             | 
            
            
              
                 
                 
               | 
              
                DAxisField
               | 
              
            D axis components.
             | 
            
            
              
                 
                 
               | 
              
                DF
               | 
              
            Displacement factor - Cosine of the phase angle between fundamental frequency voltage and current phasors.
             | 
            
            
              
                 
                 
               | 
              
                DFArith
               | 
              
            Displacement factor - IEEE arithmetic calculations.
             | 
            
            
              
                 
                 
               | 
              
                DFCoSDemand
               | 
              
            Value of displacement power factor coincident with apparent power demand.
             | 
            
            
              
                 
                 
               | 
              
                DFDemand
               | 
              
            Value of displacement power factor for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                DFVector
               | 
              
            Displacement factor - IEEE vector calculations.
             | 
            
            
              
                 
                 
               | 
              
                EvenTHD
               | 
              
            Even harmonic distortion (%).
             | 
            
            
              
                 
                 
               | 
              
                EvenTHDRMS
               | 
              
            Even THD normalized to RMS.
             | 
            
            
              
                 
                 
               | 
              
                FlkrFreqMax
               | 
              
            Frequence of maximum flicker harmonic.
             | 
            
            
              
                 
                 
               | 
              
                FlkrMagAvg
               | 
              
            Flicker average RMS value.
             | 
            
            
              
                 
                 
               | 
              
                FlkrMagMax
               | 
              
            Magnitude of maximum flicker harmonic.
             | 
            
            
              
                 
                 
               | 
              
                FlkrMaxDVV
               | 
              
            dV/V base.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPiLPF
               | 
              
            Pi LPF.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPiMax
               | 
              
            Pi max.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPiRoot
               | 
              
            Pi root.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPiRootLPF
               | 
              
            Pi root LPF.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPLT
               | 
              
            Long term flicker.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPLTSlide
               | 
              
            Sliding PLT.
             | 
            
            
              
                 
                 
               | 
              
                FlkrPST
               | 
              
            Short term flicker.
             | 
            
            
              
                 
                 
               | 
              
                FlkrSpectrum
               | 
              
            Flicker spectrum VRMS(F).
             | 
            
            
              
                 
                 
               | 
              
                FlkrWgtAvg
               | 
              
            Spectrum weighted average.
             | 
            
            
              
                 
                 
               | 
              
                FormFactor
               | 
              
            Form factor.
             | 
            
            
              
                 
                 
               | 
              
                Frequency
               | 
              
            Frequency.
             | 
            
            
              
                 
                 
               | 
              
                HRMS
               | 
              
            Harmonic RMS.
             | 
            
            
              
                 
                 
               | 
              
                IHRMS
               | 
              
            Interharmonic RMS.
             | 
            
            
              
                 
                 
               | 
              
                Instantaneous
               | 
              
            Instantaneous f(t).
             | 
            
            
              
                 
                 
               | 
              
                IT
               | 
              
            IT.
             | 
            
            
              
                 
                 
               | 
              
                KFactor
               | 
              
            Transformer K factor.
             | 
            
            
              
                 
                 
               | 
              
                Linear
               | 
              
            Linear position.
             | 
            
            
              
                 
                 
               | 
              
                None
               | 
              
            No quantity characteristic.
             | 
            
            
              
                 
                 
               | 
              
                OddTHD
               | 
              
            Odd harmonic distortion (%).
             | 
            
            
              
                 
                 
               | 
              
                OddTHDRMS
               | 
              
            Odd THD normalized to RMS.
             | 
            
            
              
                 
                 
               | 
              
                P
               | 
              
            Real power (watts).
             | 
            
            
              
                 
                 
               | 
              
                PCoQDemand
               | 
              
            Value of active power coincident with reactive power demand.
             | 
            
            
              
                 
                 
               | 
              
                PCoSDemand
               | 
              
            Value of active power coincident with apparent power demand.
             | 
            
            
              
                 
                 
               | 
              
                PDemand
               | 
              
            Value of active power for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                Peak
               | 
              
            Peak value.
             | 
            
            
              
                 
                 
               | 
              
                PF
               | 
              
            True power factor - (Vrms * Irms) / P.
             | 
            
            
              
                 
                 
               | 
              
                PFArith
               | 
              
            True power factor - IEEE arithmetic calculations.
             | 
            
            
              
                 
                 
               | 
              
                PFCoPDemand
               | 
              
            Value of true power factor coincident with active power demand.
             | 
            
            
              
                 
                 
               | 
              
                PFCoQDemand
               | 
              
            Value of true power factor coincident with reactive power demand.
             | 
            
            
              
                 
                 
               | 
              
                PFCoSDemand
               | 
              
            Value of true power factor coincident with apparent power demand.
             | 
            
            
              
                 
                 
               | 
              
                PFDemand
               | 
              
            Value of true power factor for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                PFund
               | 
              
            Value of fundamental frequency real power.
             | 
            
            
              
                 
                 
               | 
              
                PFVector
               | 
              
            True power factor - IEEE vector calculations.
             | 
            
            
              
                 
                 
               | 
              
                PHarmonic
               | 
              
            Net harmonic active power.
             | 
            
            
              
                 
                 
               | 
              
                PHarmonicUnsigned
               | 
              
            Arithmetic sum harmonic active power.
             | 
            
            
              
                 
                 
               | 
              
                PIntg
               | 
              
            Value of active power integrated over time (Energy - watt-hours).
             | 
            
            
              
                 
                 
               | 
              
                PIntgNeg
               | 
              
            Value of active power integrated over time (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                PIntgNegFund
               | 
              
            Value of active fundamental frequency power integrated over time
            (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                PIntgPos
               | 
              
            Value of active power integrated over time (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                PIntgPosFund
               | 
              
            Value of active fundamental frequency power integrated over time
            (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                PIVLIntg
               | 
              
            Value of active power integrated over time (Energy - watt-hours).
             | 
            
            
              
                 
                 
               | 
              
                PIVLIntgNeg
               | 
              
            Value of active power integrated over time (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                PIVLIntgNegFund
               | 
              
            Value of active fundamental frequency power integrated over time
            (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                PIVLIntgPos
               | 
              
            Value of active power integrated over time (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                PIVLIntgPosFund
               | 
              
            Value of active fundamental frequency power integrated over time
            (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                PPeakDemand
               | 
              
            Peak active power demand.
             | 
            
            
              
                 
                 
               | 
              
                PPredDemand
               | 
              
            Predicted value of active power for current demand interval.
             | 
            
            
              
                 
                 
               | 
              
                Q
               | 
              
            Reactive power (VAR).
             | 
            
            
              
                 
                 
               | 
              
                QAxis
               | 
              
            Q axis components.
             | 
            
            
              
                 
                 
               | 
              
                QCoPDemand
               | 
              
            Value of reactive power coincident with active power demand.
             | 
            
            
              
                 
                 
               | 
              
                QCoSDemand
               | 
              
            Value of reactive power coincident with apparent power demand.
             | 
            
            
              
                 
                 
               | 
              
                QDemand
               | 
              
            Value of reactive power for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                QFund
               | 
              
            Value of the reactive power at fundamental frequency.
             | 
            
            
              
                 
                 
               | 
              
                QIntg
               | 
              
            Value of reactive power integrated over time (var-hours).
             | 
            
            
              
                 
                 
               | 
              
                QIntgNeg
               | 
              
            Value of reactive power integrated over time (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                QIntgNegFund
               | 
              
            Value of fundamental frequency reactive power integrated over time
            (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                QIntgPos
               | 
              
            Value of reactive power integrated over time (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                QIntgPosFund
               | 
              
            Value of fundamental frequency reactive power integrated over time
            (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                QIVLIntg
               | 
              
            Value of reactive power integrated over time (var-hours).
             | 
            
            
              
                 
                 
               | 
              
                QIVLIntgNeg
               | 
              
            Value of reactive power integrated over time (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                QIVLIntgNegFund
               | 
              
            Value of fundamental frequency reactive power integrated over time
            (Energy - watt-hours) in the negative direction (away from load).
             | 
            
            
              
                 
                 
               | 
              
                QIVLIntgPos
               | 
              
            Value of reactive power integrated over time (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                QIVLIntgPosFund
               | 
              
            Value of fundamental frequency reactive power integrated over time
            (Energy - watt-hours) in the positive direction (toward load).
             | 
            
            
              
                 
                 
               | 
              
                QPeakDemand
               | 
              
            Peak reactive power demand.
             | 
            
            
              
                 
                 
               | 
              
                QPredDemand
               | 
              
            Predicted value of reactive power for current demand interval.
             | 
            
            
              
                 
                 
               | 
              
                RMS
               | 
              
            RMS value.
             | 
            
            
              
                 
                 
               | 
              
                RMSDemand
               | 
              
            RMS value of current for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                RMSPeakDemand
               | 
              
            Peak demand current.
             | 
            
            
              
                 
                 
               | 
              
                Rotational
               | 
              
            Rotational position.
             | 
            
            
              
                 
                 
               | 
              
                S
               | 
              
            Apparent power (VA).
             | 
            
            
              
                 
                 
               | 
              
                S0S1
               | 
              
            Zero sequence component unbalance (%).
             | 
            
            
              
                 
                 
               | 
              
                S2S1
               | 
              
            Negative sequence component unbalance (%).
             | 
            
            
              
                 
                 
               | 
              
                SArith
               | 
              
            Value of apparent power - IEEE arithmetic calculations.
             | 
            
            
              
                 
                 
               | 
              
                SArithFund
               | 
              
            Value of fundamental frequency apparent power - IEEE arithmetic calculations.
             | 
            
            
              
                 
                 
               | 
              
                SCoPDemand
               | 
              
            Apparent power coincident with active power demand.
             | 
            
            
              
                 
                 
               | 
              
                SCoQDemand
               | 
              
            Apparent power coincident with reactive power demand.
             | 
            
            
              
                 
                 
               | 
              
                SDemand
               | 
              
            Value of apparent power for a demand interval.
             | 
            
            
              
                 
                 
               | 
              
                SFund
               | 
              
            Value of fundamental frequency apparent power.
             | 
            
            
              
                 
                 
               | 
              
                SIntg
               | 
              
            Value of apparent power integrated over time (VA-hours).
             | 
            
            
              
                 
                 
               | 
              
                SIntgFund
               | 
              
            Value of fundamental frequency apparent power integrated over time (VA-hours).
             | 
            
            
              
                 
                 
               | 
              
                SIVLIntg
               | 
              
            Value of apparent power integrated over time (VA-hours).
             | 
            
            
              
                 
                 
               | 
              
                SIVLIntgFund
               | 
              
            Value of fundamental frequency apparent power integrated over time (VA-hours).
             | 
            
            
              
                 
                 
               | 
              
                SNeg
               | 
              
            Negative sequence component.
             | 
            
            
              
                 
                 
               | 
              
                SPeakDemand
               | 
              
            Peak apparent power demand.
             | 
            
            
              
                 
                 
               | 
              
                Spectra
               | 
              
            Spectra F(F).
             | 
            
            
              
                 
                 
               | 
              
                SpectraHGroup
               | 
              
            Spectra by harmonic group index.
             | 
            
            
              
                 
                 
               | 
              
                SpectraIGroup
               | 
              
            Spectra by interharmonic group index.
             | 
            
            
              
                 
                 
               | 
              
                SPos
               | 
              
            Positive sequence component.
             | 
            
            
              
                 
                 
               | 
              
                SPredDemand
               | 
              
            Predicted value of apparent power for current demand interval.
             | 
            
            
              
                 
                 
               | 
              
                Status
               | 
              
            Status data.
             | 
            
            
              
                 
                 
               | 
              
                SVector
               | 
              
            Value of apparent power - IEEE vector calculations.
             | 
            
            
              
                 
                 
               | 
              
                SVectorFund
               | 
              
            Value of fundamental frequency apparent power - IEEE vector calculations.
             | 
            
            
              
                 
                 
               | 
              
                SZero
               | 
              
            Zero sequence component.
             | 
            
            
              
                 
                 
               | 
              
                TDD
               | 
              
            Total demand distortion.
             | 
            
            
              
                 
                 
               | 
              
                TID
               | 
              
            Total interharmonic distortion.
             | 
            
            
              
                 
                 
               | 
              
                TIDRMS
               | 
              
            Total interharmonic distortion normalized to RMS.
             | 
            
            
              
                 
                 
               | 
              
                TIF
               | 
              
            TIF.
             | 
            
            
              
                 
                 
               | 
              
                TIFRMS
               | 
              
            TIF normalized to RMS.
             | 
            
            
              
                 
                 
               | 
              
                TotalTHD
               | 
              
            Total harmonic distortion (%).
             | 
            
            
              
                 
                 
               | 
              
                TotalTHDRMS
               | 
              
            Total THD normalized to RMS.
             | 
            
            
              
                 
                 
               | 
              
                TransferFunc
               | 
              
            Transfer function.
             |